Fire hydrant

Live response resource

Fire Hydrant Tracker

Use your current device location to find and compare nearby hydrants.

Locating...
Following

Nightwatch coverage

On-Call Today

Today
PrimaryLoading…
SecondaryLoading…
Loading distance data...
Your locationYour location
Fire hydrants
Lat: –, Lng: –, Acc: – m

Nearby Hydrants

Start Hydrant Inspection
Loading hydrant data...

Your current location

Determining your location...

If location is blocked, allow Location for this site in your browser settings, then tap Refresh Location.

Newsom Fire & Rescue

Newsom Run Report

Explore the same incident-report workflow used in the Hub. This demonstration does not retain any entries.

Read-Only Sample Report

Draft storage is disabled in this demonstration.

You may explore the fields, but text and photographs are never uploaded or retained.

Photo storage is disabled.

Tap a section heading to open or close it. Required fields are marked with an asterisk.
Incident & responseDate, times, address, incident type, and narrative
Response timelineUse 24-hour time
Incident information
Mutual aid & agenciesAssisting departments, aid given, EMS, and police
Incident-specific detailsOnly information relevant to the selected incident type appears here
Personnel assignmentsSelect every member assigned to each responding unit
Demonstration onlyEmail, archive, and submission actions are disabled.

Operational reference library

SOPs, SOGs & Procedures

Quick access to department policies, incident procedures, and first-responder protocols.

Department SOPs and SOGs

Search by apparatus, response type, safety topic, or program name, then open the current PDF or download the original Word copy.

5documents shown PDF and Word copies available
Response guidelineTower Operations

Response Guidelines for Tower 1

Response order, staffing, apparatus placement, commercial calls, and mutual-aid approval for Tower 1.

  • Residential response
  • Commercial calls
  • Mutual aid
2 PDF pagesRevised September 15, 2026
SOGTower Operations

Tower One Standard Operating Guidelines

Safety guidance for apparatus setup, aerial and platform operations, and master-stream use.

  • Placement and setup
  • Aerial operations
  • Master-stream operations
2 PDF pagesRevised September 15, 2026
SOPPersonnel Programs

Take-Home Squad Standard Operating Guidelines

Eligibility, scheduling, vehicle responsibilities, and administration for the Take-Home Squad Program.

  • Minimum qualifications
  • Two-week scheduling
  • Participant responsibilities
3 PDF pagesRevised September 15, 2026
Check-offDriver Training

Probationary Driver/Operator Qualification Check-Off

Qualification checklist for apparatus familiarization, driving skills, pump operations, aerial operations, and final approval.

  • Driving evaluation
  • Pump qualification
  • Aerial qualification
13 PDF pages
SOGDriver Training

Standard Operating Guidelines for Probationary Driving

Safe-driving restrictions, supervised training requirements, emergency qualification, and incident reporting for probationary members.

  • Driving restrictions
  • Supervised training
  • Emergency qualification
4 PDF pages

Incident Procedures

This is to guide members on Sizing a scene for incoming units

  • A brief description of the building
    • Construction Type (Woodframe, Brick & Mortar, Commercial, etc.)
    • Occupancy (house, apartment, strip mall, box store, high-rise, church, etc.)
    • Size (large, medium, small, or dimensions, i.e. 100'x150')
    • Height/Number of floors
  • Incident Conditions
    • Nothing Showing
    • Smoke Showing (amount, location, color, pressure)
    • Fire Showing (amount and location)
    • Exposures
  • Brief description of the action taken by officer and crew members
    • Select the option for Command (Offensive or Defensive)
    • Actions of Crew Members (See Example 1)
  • Any Safety Hazards
  • Identification and location of Incident Command
  • Request required resources when necessary
Radio example

"Engine Eleven is on scene of a one-story, single-family structure. Flames are visible through the windows on the A side of the structure. The life safety status is unknown. Engine Eleven is deploying a hose line for an interior attack. The next engine on scene will be assigned water supply. Engine Eleven will be establishing 7th Street Incident Command.”

360 Assessment

After initial size-up, perform 360 Assessment

  • 360 Radio Report should include:
    • Report Findings
    • Search/Rescue Opportunities
    • Confirm Strategy (Offensive vs Defensive)
    • Credible information given by occupant or bystanders
    • Report on Exposures
    • Update on fire/smoke location and conditions
    • Flow Path (if determined)
    • Utilities secured during 360
    • Confirm assignments of deployed resources
    • Request additonal resources as needed
    • Any other pertinent information

First Responder Protocols

Search by protocol number or topic, then open the exact page you need.

First Responder Protocols v2.3Last updated: Feburary 12, 2019
72protocols shown Open full manual

General

17
1.4

Hazardous Material (HAZMAT) Scene Management

PDF page 9
Open protocol

Procedures

10
2.9

Oxygenation, Ventilation, and Pulse Oximetry

PDF page 34
Open protocol

Assessment Tools

6

Medical Treatments

24
4.19

Pediatric Respiratory Distress / Arrest

PDF page 66
Open protocol

Trauma Treatments

10

Appendix

5
Appendix A

Exposure Procedure / Needle Stick

PDF page 84
Open protocol
Appendix E

Emergency Medical Application Tourniquet

PDF page 91
Open protocol

Document Information

Version

2.4

Last Updated

February 12, 2019

File Size

1.2 MB

Description

Sample first responder protocols for the Newsom Fire & Rescue demonstration.